Industrial Waste Incinerator Manufacturer,Supplier and Exporter in USA

Industrial Waste Incinerator

Product Code : JA-I-2434
Lss America is a leading Industrial Waste Incinerator Manufacturer,and suppliers in USA, Industrial Waste Incinerator Manufacturer,and suppliers in South Africa.Industrial Waste Incinerator Suppliers in Mozambique,Industrial Waste Incinerator A quality product from Engineering Lab Equipments ideal for use in School Laboratories in developing countries of Asia, Africa and South Africa in Supplier Kenya, Southern African region, Botswana, Lesotho, Malawi, Angola, Namibia, Zambia, Zimbabwe. Djibouti, Ethiopia,Madagascar, Mauritius, Rwanda, Seychelles, Tanzania and Uganda.

Industrial Waste Incinerator

We are prominent manufacturers and suppliers of Industrial Waste Incinerator.

These systems effectively dispose of industrial wastes without polluting the environment.

Their process involves little time making them highly fuel efficient.

They have been manufactured using standard materials and have a long shelf life.

They have been economically priced.

Smoke and fuel gases from the primary chamber are directed to re burn the smoke and fuel gases to ensure proper combustion in secondary chamber and consequently a complete smoke free operation so that there is no colour or smoke in the chimney.

It shall be designed to have a complete destruction of the flue gases.

Where fresh air in induced to lower the temp. of the flue gases to avoid formation of the gases to enable heavier fly ash particle settle down.

A blower is provided for this application.

Features:-

Supported with supporting structure made from IS structural section Material

It shall be sturdy to with stand any stress or stain formed during the operation

Specifications:-

Primary Chamber:-

Type:- Dual chamber  Primary chamber

Dia:- 800 mm      

Height:- 1500 mm

Material of construction:- Other body made from quality plate

Material:- Mild steel

Thickness:- 6 mm

Total thickness of insulation:- 230 mm

Operating temp. (Primary chamber):- 800 ± 50 deg.C

Operating temp. (Secondary chamber):- 1050 ± 50 deg.C

Secondary Chamber:-

Dia:- 900 mm

Height:- 1500 mm

Retention tune:- 2 seconds

Temp. of outer body of the chamber:-

 

Shall not exceed 35 deg. c. or above


   