Liquid Chromatography Digital System Manufacturer,Supplier and Exporter in USA

Liquid Chromatography Digital System

Product Code : JA-CELE-9106
Lss America is a leading Liquid Chromatography Digital System Manufacturer,and suppliers in USA, Liquid Chromatography Digital System Manufacturer,and suppliers in South Africa.Liquid Chromatography Digital System Suppliers in Mozambique,Liquid Chromatography Digital System A quality product from Engineering Lab Equipments ideal for use in School Laboratories in developing countries of Asia, Africa and South Africa in Supplier Kenya, Southern African region, Botswana, Lesotho, Malawi, Angola, Namibia, Zambia, Zimbabwe. Djibouti, Ethiopia,Madagascar, Mauritius, Rwanda, Seychelles, Tanzania and Uganda.

Liquid Chromatography Digital System
Specification:- 

HPLC:-
Ultra speed data processing by Network HPLC.
Designed for all you need in the lab.
Enhanced superior performance.
Versatile dedicated applications.
Accurate and reliable data.
Stylish and compact design.

Quaternary Pump:-
Operating principle: Parallel dual-plunger pump, Low-pressure gradient.
Number of Solvents: up to 4 solvents.
Gradient formation: 4-channel mixing valve.
Composition Precision: < 0.1%.
Composition Accuracy: < 0.5%.

Binary Pump:-
Operating principle: Double parallel dual-plunger pump,
High-pressure gradient.
Configure with Gradient pump.

Vacuum Degasser:-
Number of channel: 4 channels.
Maximum flow rate: 10ml/min per channel 0~2.0ml/min per channel for 70% Gas Removed from Methanol.
Internal volume per channel: 925 ul per channel.
Materials in contact with the solvent.
Teflon AF, PEEK, and Glass-filled PTEE.

Column Compartment:-
Temperature range: 4°C (Cooling) - 90°C
Temperature stability: ± 0.05°C
Temperature accuracy: ±0.5°C
Column capacity: Max. 3 ea of 30 cm column (Analytical)
Max. 2 ea of 30 cm column (Semi-Prep)

UV/Vis Detector:-
Wavelength Range: 190~900nm (Dual wavelength)
Data collection rate: up to 50Hz
Noise level: < ±0.5 × 10-5 AU, 254nm, dry cell
Drift: < 1 × 10-4 AU/hr
Linearity: > 99.5% for 2.5AU (acetone, 254nm)

PDA Detector:-
No. of PDA Channel: 1024
Wavelength: 190 ~ 950nm
Noise Level: 2 × 10-5 AU (Empty Cell, 1 sec Rise Time, 254nm)
Drift: 2 × 10-4 AU/hr (Baseline Correction), 0.001AU/hr (Room Temp)
Wavelength Accuracy: 1nm (HY-1 Holmium Oxide Filter)

RI Detector:-
RI Range: 1.00~1.75 RIU
Noise: ≤ 5 × 10-9 RIU (Analytical) / ≤ 10 × 10-8 RIU (Semi-prep)
Flow Cell Volume: 9 ul (Analytical) / 7 ul (Semi-prep)

   